Page 36 - Commercial Catalogue 2011

This is a SEO version of Commercial Catalogue 2011. Click here to view full version

« Previous Page Table of Contents Next Page »
31 Commercial Catalogue
Tel: +44 (0) 1923 284151 www.tropicalmarinecentre.co.uk
Code Grp Product
Material of
Inlet/Outlet Bio-MediaType Media Recommended Max. System Max. Livestock Approx
Construction Connections
Volume Flow Rate Volume at Mass at
Shipping
(l)
Application Application Weight
l/min m
3
/hr Level 3 (l) Level 3 (kg) vol (kg)
7921 FI TBT 5200P
Polypropylene/
1”/1
1 / 2
1” TMC
35
15
1
2500
8
15
Trickle Bio-Tower U-PVC
Bio-Rings
7923 FI TBT 5300P
Polypropylene/
1”/1
1 / 2
1” TMC
70
35
2
5000
15
28
Trickle Bio-Tower U-PVC
Bio-Rings
7942 FI TBT800P
HDPE/U-PVC
2”/3”
1” TMC
500
180
11
35,000
100 On applic.
Trickle Bio-Tower
Bio-Rings
7943 FI TBT 1000P HDPE/U-PVC
2”/3”
1” TMC
800
315
19
60,000
180 On applic.
Trickle Bio-Tower
Bio-Rings
Ask for separate
spec sheet
TMC Re-Gas/Bio-Towers have a number of unique design features including:-
• Rotating spray bar with glass and teflon bearing.This special
bearing, used in all TMC Re-Gas/Bio-Towers, is unique.Water
does not pass through the actual bearing itself which, together
with the specially designed bearing housing, ensures the spray bar
mechanism rotates continuously, unlike those used in
conventional bearings. Bar rotation is kinetically driven by the
pressure of the water exiting the bar.
• Side wall flow deflector rings. Specially designed flow deflector
rings are included with TMC Re-Gas/Bio-Towers to prevent
water flow channelling down the sides of the filters.
• Double o-ring outlet boss.
All TMC Re-Gas/Bio-Towers
feature our unique, flexible
double o-ring boss system
for easy service and the
simple removal and
replacement of pipework
and components.
All units utilise our TMC Bio-Rings with an approximate surface area of 210m
2
/m
3
, and a biological
capacity of a minimum of 140g of TAN processed per m
3
of media per 24 hours. Flow rates specified
are designed to be 30m
3
/hr per m
2
of cross-sectional filter area.
Technical Fact