Code Grp Product
Total No Total UVc Radiation Approx Inlet/ Max.Flow Max Re-Circ Syst Un-Packed Approx
of 55W Emitted@ 253.7 nm Input Outlet Rate at Volume based on Dimensions Shipping
Lamps (18Wper lamp Current Size Application 4x/hr turnover at L x H x D Weight
when new) (W)
(A)
Level 3 Application Level 3
(mm)
( kg)
l/min m
3
/hr
(l)
Single Phase 220-240v 50Hz
7012-55 FA P1-55WCommercial
1
18
0.22
2” 30
2
500
930x111x300 5.00
UV Steriliser
7000-55 FA P2 – 110WCommercial
2
36
0.44
2” 65
4
1000
930x160x278
6.85
UV Steriliser
7001-55 FA P4 – 220WCommercial
4
72
0.88
2” 130
8
2000
930x505x460 16.7
UV Steriliser – Floor Mounted
7001W-55 FA P4 – 220WCommercial
4
72
0.88
2” 130
8
2000
930x220x780 14.9
UV Steriliser –Wall Mounted
7002-55 FA P6 – 330WCommercial
6
108
1.32
2” 200 12
3000
930x644x460 24.55
UV Steriliser – Floor Mounted
7002W-55 FA P6 – 330WCommercial
6
108
1.32
2” 200 12
3000
930x220x920 22.05
UV Steriliser –Wall Mounted
7003-55 FA P8 – 440WCommercial
8
144
1.76
2” 265 16
4000
930x780x460 30.8
UV Steriliser – Floor Mounted
7006-55 FA P10 – 550WCommercial
10
180
2.20
2” 330 20
5000
930x662x495 37.2
UV Steriliser – Floor Mounted
7010-55 FA P6Twin – 660W Commercial 12
216
2.64 2 x 2” 400 24
6000
930x735x520 41.0
UV Steriliser – Floor Mounted
7011-55 FA P8Twin - 880WCommercial
16
288
3.52 2 x 2” 530 32
8000
930x885x520 52.0
UV Steriliser - Floor Mounted
7009-55 FA P10Twin - 1100WCommercial 20
360
4.40 2 x 2” 660 40
10000
930x883x520 60.6
V Steriliser - Floor Mounted
P8 Twin Floor Standing unit
Larger units can be manufactured on request.
For smaller applications, our V
2
ecton UV
Sterilisers can be used.
The pressure drop in UVs is less than 2psi in all
our units.
All our UVs are designed to operate
indoors/covered (not below freezing point).
IMPORTANT
Each TMC Commercial UV Steriliser uses a high frequency control gear, which should, ideally, be operated on its
own power supply circuit. If this is not possible then it is important that the UV Steriliser is not installed on a
circuit that may be susceptible to induced loads that lead to high energy surges (spikes), as
these high energy
surges will damage the UV contol gear.
Examples of equipment that could potentially cause high energy surges or spikes are: most large electric motors
including some water pumps and light fittings with igniters, such as floodlights.
High frequency control gears should not be operated on the same power circuit as traditional magnetic ballasts.