Page 63 - Commercial Catalogue 2011

This is a SEO version of Commercial Catalogue 2011. Click here to view full version

« Previous Page Table of Contents Next Page »
Code Grp Product
Power/kW Horse Power Current Colour
Inlet/Outlet Approx.
Dims
P1 In P2 Out
(A)
Size (" P) Shipping WxLxH
Wt - mass (kg)
SinglePhasePumps220–240v
7290 FF Argonaut AG8 pump
0.29 0.19 N/A
1.45
Blue
1
1 / 2
/1
1 / 2
7.7
195 x 477 x 276
7291 FF Argonaut AG10 pump
0.36 0.25 N/A
1.70
Blue
1
1 / 2
/1
1 / 2
7.8
195 x 477 x 276
7292 FF Argonaut AG14 pump
0.49 0.37 N/A
2.80
Blue
1
1 / 2
/1
1 / 2
7.9
195 x 477 x 276
7293 FF Argonaut AG16 pump
0.67 0.49 N/A
3.00
Blue
1
1 / 2
/1
1 / 2
8.0
195 x 477 x 276
ITT Argonaut AG Series Pumps
• Incorporates a new motor giving 25% power saving
for the same performance.
• High flow rates.
• Unrivalled whisper running.
• Low running costs.
• Supplied with 1
1 / 2
" sockets for easy connection to rigid
pipe.
• Polypropylene tank and stainless AISI 316 steel shaft.
• Self priming up to 1.8m.
AG Argonaut Performance Curves
InstallationTip
Calculate the total volume of water that will be "in suspension" in the pipework, and ensure that the
sump is big enough to avoid overfilling in the event of a power interruption.This volume (in m
3
) can
easily be calculated by using the following simple equation:-
Volume = 3.14 x R
2
x L
where R is half of the internal diameter of the pipe (in metres)
and L is the total length of pipe (in metres).
The table on the right can be used as a guideline for imperial pipe sizes.
Please note that different grade pipes will have different wall thickness’ –
the thicker the wall the smaller the internal diameter (ID), as the external
diameter is always constant.
Pipe size
ID mm
1 / 2
"
19
3 / 4
"
23
1"
29
1
1 / 2
"
43
2"
53
3"
80
4"
104
www.tropicalmarinecentre.co.uk Tel: +44 (0) 1923 284151 Commercial Catalogue 58