63 Commercial Catalogue
Tel: +44 (0) 1923 284151 www.tropicalmarinecentre.co.uk
Code Grp Product
Power Current Minimum Maximum
Inlet/Outlet Approx
(kW) Consumption Flow Rate Flow Rate Size (“) Shipping
(A)
l/min m
3
/hr l/min m
3
/hr
Wt (kg)
Single Phase (230V)
8009 EL Elecro 3kWTitanium Electric Heater
3
13
16.7 1.0 166.67 10
1
1 / 2
4
8010 EL Elecro 6kWTitanium Electric Heater
6
27
16.7 1.0 166.67 10
1
1 / 2
5
8011 EL Elecro 8kW Titanium Electric Heater
8
35
16.7 1.0 166.67 10
1
1 / 2
5
8024 EL Elecro 1kW Stainless Steel Electric Heater
1
5
16.7 1.0 166.67 10
1
1 / 2
4
8025 EL Elecro 2kW Stainless Steel Electric Heater
2
9
16.7 1.0 166.67 10
1
1 / 2
4
8026 EL Elecro 3kW Stainless Steel Electric Heater
3
13
16.7 1.0 166.67 10
1
1 / 2
4
8027 EL Elecro 4kW Stainless Steel Electric Heater
4
18
16.7 1.0 166.67 10
1
1 / 2
4
8028 EL Elecro 6kW Stainless Steel Electric Heater
6
27
16.7 1.0 166.67 10
1
1 / 2
5
8029 EL Elecro 8kW Stainless Steel Electric Heater
8
35
16.7 1.0 166.67 10
1
1 / 2
6
Three Phase (400V)
8012 EL Elecro 6kW Titanium Electric Heater (400V)
6
9
16.7 1.0 166.67 10
1
1 / 2
6
8013 EL Elecro 8kW Titanium Electric Heater (400V)
8
13
16.7 1.0 166.67 10
1
1 / 2
6
8030 EL Elecro 6kW Stainless Steel Electric Heater
6
9
16.7 1.0 166.67 10
1
1 / 2
6
8031 EL Elecro 8kW Stainless Steel Electric Heater
8
13
16.7 1.0 166.67 10
1
1 / 2
6
ElecroTitanium Heaters
Elecro Titanium Digital Heaters
are a new range of reliable, economical
heaters that offer the user precise
temperature control (+/- 0.5C).The
highly sensitive flow switch, high limiting
safety thermostat and integral
contactor/relay are standard safety
features, along with a digital temperature
display.The titanium flow tube and
elements ensure the heater’s suitability
for use on all freshwater and saltwater
applications.The flow switch is reversible,
which means that the unit can be installed with the flow entering the unit from either side. All units are
supplied with 1
1 / 2
" solvent weld unions.
Key Features:-
• Pure titanium flow tube
• Pure titanium element(s)
• Digital temperature display & control
• External reversible flow switch
• High limiting safety thermostat
• Integral contactor/relay
• Circuit protection delay switching
Heaters should be installed close to the filtration system, but must not be installed over reservoirs or other
bodies of water. Units must be mounted horizontally and fixed to a wall. Heaters should be installed at the
lowest level of the hydraulic circuit to ensure that they are always filled with water.
Technical Fact
InstallationTip
Stainless steel units are suitable for use in freshwater
systems only.
Heaters and chillers that are to be utilised in saltwater
and brackish applications should be manufactured from
titanium only. Stainless steel units will corrode!